10 Meter EMC Test Chamber
Panashield's 10 meter EMC anechoic chamber provides a full compliance test facility for performing radiated emissions measurements to EN50147 part 2 and ANSI C63.4 at test distances up to 10 meters Normalised Site Attenuation (NSA) of better than +/-3.5dB is attained within a 3 meter diameter quiet zone at a 10 meter test distance. NSA measurements can also be made at 5 meter and 3 meter test distances.

The chamber design is also suitable to perform full compliance radiated immunity testing per EN / IEC61000-4-3 and other International standards. This 10 meter EMC test chamber is constructed using the versatile Panabolt modular panel RF shielding system providing a high level of shielding integrity.
Nominal Size:
- 18.6 m long x 12.6 m wide x 8.1 m high (8.4 to 8.6 m with raised ground plane reflective floor)
Frequency Range:
- Emissions: 30 MHz to 18 GHz / 40 GHz
- Immunity: 26 MHz to 18 GHz / 40 GHz
Standard Features:
- Self supporting structure
- Single leaf RF shielded door 1200 wide x 2100 mm high or double leaf door
1800 wide x 2100 mm high - Two connector panels with two type N connectors
- Six waveguide vents 300 x 300 mm
- 30 amp filters for power
- 5 amp filters for individual lighting
- Earth/ground stud
- Full installation
Absorber Lining:
- Walls and ceiling covered with ferrite absorber panels
- Section of removable ferrite panels for positioning on floor between EUT and antenna for
immunity testing. - Hybrid absorber on critical area of EUT and antenna end walls
- Hybrid absorber on critical area of side walls and ceiling
- Hybrid absorber for placing over an area of the ferrite floor patch
Typical Options:
- RF shielded control room and also option for amplifier room
- Larger RF shielded door
- Raised ground plane floor
- Integrated turntable, 2 m, 3 m or 4 m diameter
- Variable height antenna tower/mast
- Dual controller with fibre optic interface
- CCTV monitoring system
- Additional filters
- RF shielding effectiveness measurement
- Field Uniformity measurement
- Normalised site attenuation (NSA) measurement
Standards:
- EN50157 part 2
- ANSI C 63.4-2000
- EN55011 / CISPR 11
- EN55016 / CISPR 16
- EN55022 / CISPR 22
- EN / IEC 61000-4-3
- SAE Various specifications
EMC Chambers
For More Information
Panashield, Inc.
185 West Norwalk Road #R
Norwalk, CT 06850
(203) 866-5888
help@panashield.com